The
circuit was designed to provide an alarm system against any form of
burglary based on the operation of CMOS 4011 where a high output would
only result when any of the input is low.
Terminology
Zone – refers to an alarm control panel’s input from a protective
circuit which divides the alarm system into separate independent areas
of protection based on function which may include medical, fire,
intrusion, or critical condition monitoring
Burglar Alarm - one way of preventing break-in’s into one’s property,
not only to protect the possessions but the occupants as well; can
prevent the havoc and disruption caused by theft and break-in’BC547 –
NPN small signal transistors designed for general purpose switching and
amplification due to its low voltage, low current and three different
gain selections CMOS 4011 – a quad 2-input NAND gate integrated circuit,
generally characterized by small fluctuation in voltage supply, very
high impedance, outputs that can sink and source, one output can drive
up to 50 inputs, high speed gate propagation time, high frequency, and
low power consumption
The
zone designed in this circuit contains automatic entry and exit
intervals with a bell having its cut off timer. It can also be
applicable to other normally open and normally closed switches that
contains input devices such as magnetic reed contacts, pressure mats,
foil tapes, inertia sensors and passive infrared detectors. The buzzer
will sound if the alarm is switched on wherein the loop is in open
stage. On theother hand, as the switch turns off, the loop becomes a
closed circuit again. The alarm will operate with any type of two-way
switch.
The
circuit is being powered by a 12 V supply, which is enough for as long
as the buzzer, siren, and relay will match the supply input. The
basicoperation of the alarm occurs with the interruption of electric
current to a relay cause by deenergizing of the relay and making the
relay contacts to operate the alarm indicator. The circuit is applicable
to a single zone which can consist of a single point of contact. To
start the circuit to function, the switch S1 should be set accordingly,
but before doing this, all the LED should be properly lighting. Once the
switch has been set, there will be an allotted thirty seconds to leave
the premises which will trigger the buzzer to sound. It will only stop
sounding when the door has been closed. In doing this procedure, it will
ensure that the entry and exit operation has been restored effectively.
Upon re-entering the premises, there will be 30 seconds time allotment
to turn OFF the switch SW1. Failing to do this will trigger and energize
the relay and eventually sound the siren. This can be deactivated at
any time by turning OFF SW1. The alarm will reset, the relay will
de-energize, and the siren will be cut-off once the loop has been
restored after 15 minutes.
The delay timers in the circuit depend largely on the values and
characteristics of the components used in the circuit, due to the
manufacturing tolerances. The entry, exit and bell cut-off timer can be
modified by altering the values of resistors R9, R6 and R3 depending on
the prerequisite. By decreasing the values, the timer will also
decrease; same thing with increasing the values will increase the
timing.
Application:
A
burglar alarm system helps detect unauthorized entry onto a company’s
premises. The system sends a signal to a central monitoring center when
activated. The monitoring centers provide 24/7 service and will alert
the local police to dispatch authorities to the scene. It is a proven
fact that the risk of burglary is significantly reduced after a burglar
alarm is installed.